Conditions for use of explosion-proof electromagnetic starter

 Before choosing the explosion-proof electromagnetic starter, you need to know what you have in order to make this product in the best condition for daily use.

1. The above

Explosion-proof electromagnetic starter are not to be used in more than 2000 m altitude, because along with the elevation of ascension will not only reduce oxygen, also has a certain pressure, may the human can use, but the explosion-proof electromagnetic starter could not like humans, so it will be accompanied by a variety of failures or and performance degradation happens, of course, you can also go to factory negotiate to solve the problem of altitude, never try in the case of no negotiation in the environment.

2. The temperature

Explosion-proof electromagnetic starter environmental temperature limit of 40 degrees Celsius, and the lower limit is 5 degrees Celsius, of course not to say that the equipment will also be able to keep close to the limit temperature in the best condition, the limit temperature equipment is only able to normal operation, more than the normal movement of even after a short time can't do it, if you want to let the explosion-proof electromagnetic starter at its best, you can choose between 20 and 30 degrees Celsius environment, there is the environment also must be within a reasonable range, the temperature difference in the temperature gap between the general assembly to produce water inside the equipment.

Main characteristics of explosion-proof electromagnetic starter

3. The humidity

Generally use explosion-proof electromagnetic starter air humidity under 95 or 90 belong to normal, humidity condition is not certain, of course, but by the different environmental temperature change, such as higher temperature humidity limit will reduce, if you choose is the best environment, temperature humidity ring as long as the moment remain below 90%, if the moisture concentration is high, can take some measures to avoid appear a large number of moisture or condensate inside the equipment.

4. Liquid

You use or installation of explosion-proof electromagnetic starter environment may not be a large number of liquid or by rain and snow weather such as erosion, because although the explosion-proof electromagnetic starter has a sealing, but not absolutely sealed, if have a large amount of liquid will gradually penetrate into the device, once entered the inside will be very trouble, so when you install or use all must confirm whether there will be a liquid or in the environment affected by the weather.

5. Shock

Use explosion-proof electromagnetic starter can not appear in the environment of severe vibration and turbulence, this makes the product internal components appear loose and damaged, if it is in the absence of running off, and so on and so forth will also be able to carry on maintenance, but once the parts fall off when in running state, the device may be unable to run, even will affect other devices, so use explosion-proof electromagnetic starter place can not severe vibration and turbulence, and the installation of the product may not have more than 15% of the tilt, it makes equipment is easily affected by external things, once receivedImpact or some other impact that might break the inside of the device and make it unusable.

 